{"id":129,"date":"2019-12-26T16:34:35","date_gmt":"2019-12-26T15:34:35","guid":{"rendered":"https:\/\/www.theta-dresden.de\/?page_id=129"},"modified":"2025-09-30T09:02:50","modified_gmt":"2025-09-30T08:02:50","slug":"infrared-diagnosis","status":"publish","type":"page","link":"https:\/\/www.theta-dresden.de\/en\/infrared-diagnosis","title":{"rendered":"Infrared Diagnosis"},"content":{"rendered":"<h1 class=\"xr_tl Heading_2\"><span style=\"font-size: 24pt;\">To Determine the Residual Lifetime of Electrical Joints and Contacts using Infrared Measurement<\/span><\/h1>\n<p align=\"justify\">Elec\u00adtri\u00adcal equip\u00adment is age\u00ading \u2014 the pro\u00adduced pow\u00ader dis\u00adsi\u00adpa\u00adtion is con\u00adstant\u00adly increas\u00ading. Nev\u00ader\u00adthe\u00adless, elec\u00adtric switchgears should be oper\u00adat\u00aded as inten\u00adsive\u00adly and as long as pos\u00adsi\u00adble, since they are extreme\u00adly expensive.<\/p>\n<p>As a con\u00adse\u00adquence, such instal\u00adla\u00adtions have to be inspect\u00aded reg\u00adu\u00adlar\u00adly. In order to ensure an unin\u00adter\u00adrupt\u00aded pow\u00ader sup\u00adply dur\u00ading diag\u00adno\u00adsis, infrared cam\u00aderas are used. These allow to mea\u00adsure the tem\u00adper\u00ada\u00adtures with\u00adout direct con\u00adtact. The actu\u00adal prob\u00adlem, how\u00adev\u00ader, is not the mea\u00adsure\u00adment of the tem\u00adper\u00ada\u00adtures itself, but the eval\u00adu\u00ada\u00adtion of the mea\u00adsured val\u00adues. All pre\u00advi\u00adous meth\u00adods exclu\u00adsive\u00adly eval\u00adu\u00adate the tem\u00adper\u00ada\u00adture of junc\u00adtion with\u00adout con\u00adsid\u00ader\u00ading the influ\u00adences of envi\u00adron\u00admen\u00adtal and load con\u00addi\u00adtions.&nbsp; For this rea\u00adson it is impos\u00adsi\u00adble to make a reli\u00adable state\u00adment about the con\u00addi\u00adtion of the joints and contacts.<\/p>\n<table style=\"border-width: 0px;\">\n<tbody>\n<tr>\n<td style=\"border-width: 0px;\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-441 size-medium\" src=\"https:\/\/www.theta-dresden.de\/wp-content\/uploads\/2019\/12\/Thermografie01-150x150-2.jpg\" onmouseover=\"this.src='https:\/\/www.theta-dresden.de\/wp-content\/uploads\/2019\/12\/Thermografie02-150x150-1.jpg'\" onmouseout=\"this.src='https:\/\/www.theta-dresden.de\/wp-content\/uploads\/2019\/12\/Thermografie01-150x150-2.jpg'\" alt=\"Thermography fuse\" width=\"150\" height=\"150\"><\/td>\n<td style=\"border-width: 0px;\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-441 size-medium\" src=\"https:\/\/www.theta-dresden.de\/wp-content\/uploads\/2019\/12\/Thermografie03-150x150-1.jpg\" onmouseover=\"this.src='https:\/\/www.theta-dresden.de\/wp-content\/uploads\/2019\/12\/Thermografie04-150x150-1.jpg'\" onmouseout=\"this.src='https:\/\/www.theta-dresden.de\/wp-content\/uploads\/2019\/12\/Thermografie03-150x150-1.jpg'\" alt=\"Thermografie Pressverbinder\" width=\"150\" height=\"150\"><\/td>\n<td style=\"border-width: 0px;\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-441 size-medium\" src=\"https:\/\/www.theta-dresden.de\/wp-content\/uploads\/2019\/12\/Thermografie05-150x150-1.jpg\" onmouseover=\"this.src='https:\/\/www.theta-dresden.de\/wp-content\/uploads\/2019\/12\/Thermografie06-150x150-1.jpg'\" onmouseout=\"this.src='https:\/\/www.theta-dresden.de\/wp-content\/uploads\/2019\/12\/Thermografie05-150x150-1.jpg'\" alt=\"Thermography fuse\" width=\"150\" height=\"150\"><\/td>\n<td style=\"border-width: 0px;\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-441 size-medium\" src=\"https:\/\/www.theta-dresden.de\/wp-content\/uploads\/2019\/12\/Thermografie07-150x150-1.jpg\" onmouseover=\"this.src='https:\/\/www.theta-dresden.de\/wp-content\/uploads\/2019\/12\/Thermografie08-150x150-1.jpg'\" onmouseout=\"this.src='https:\/\/www.theta-dresden.de\/wp-content\/uploads\/2019\/12\/Thermografie07-150x150-1.jpg'\" alt=\"Thermography connector\" width=\"150\" height=\"150\"><\/td>\n<td style=\"border-width: 0px;\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-441 size-medium\" src=\"https:\/\/www.theta-dresden.de\/wp-content\/uploads\/2019\/12\/Thermografie09-150x150-1.jpg\" onmouseover=\"this.src='https:\/\/www.theta-dresden.de\/wp-content\/uploads\/2019\/12\/Thermografie10-150x150-1.jpg'\" onmouseout=\"this.src='https:\/\/www.theta-dresden.de\/wp-content\/uploads\/2019\/12\/Thermografie09-150x150-1.jpg'\" alt=\"Thermography distribution station\" width=\"150\" height=\"150\"><\/td>\n<td style=\"border-width: 0px;\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-441 size-medium\" src=\"https:\/\/www.theta-dresden.de\/wp-content\/uploads\/2019\/12\/Thermografie11-150x150-1.jpg\" onmouseover=\"this.src='https:\/\/www.theta-dresden.de\/wp-content\/uploads\/2019\/12\/Thermografie12-150x150-1.jpg'\" onmouseout=\"this.src='https:\/\/www.theta-dresden.de\/wp-content\/uploads\/2019\/12\/Thermografie11-150x150-1.jpg'\" alt=\"Thermography distribution station\" width=\"150\" height=\"150\"><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p align=\"justify\">There\u00adfore, <span class=\"caps\">THETA<\/span>, the Insti\u00adtute of High\u00advolt\u00adage and High\u00adcur\u00adrent at Dres\u00adden Uni\u00adver\u00adsi\u00adty of Tech\u00adnol\u00ado\u00adgy, <span class=\"caps\">RIBE<\/span> GmbH <span class=\"amp\">&amp;<\/span> Co. <span class=\"caps\">KG<\/span> Elek\u00adtroar\u00adma\u00adturen and Siemens <span class=\"caps\">AG<\/span> I<span class=\"amp\">&amp;<\/span>S <span class=\"caps\">IS<\/span> <span class=\"caps\">PGD<\/span> 5 have joint\u00adly devel\u00adoped a method which allows to deter\u00admine the resid\u00adual life\u00adtime of elec\u00adtri\u00adcal instal\u00adla\u00adtions out of their respec\u00adtive tem\u00adper\u00ada\u00adtures, ambi\u00adent con\u00addi\u00adtions and loads. There has been held an Euro\u00adpean patent on this method. The reli\u00adable infor\u00adma\u00adtion that you can gain with the help of our infrared diag\u00adno\u00adsis puts you into the posi\u00adtion to min\u00adimise the risk of fail\u00adure of your elec\u00adtri\u00adcal instal\u00adla\u00adtions and to plan a state-ori\u00aden\u00adtat\u00aded maintenance.<\/p>\n<p align=\"justify\">Watch our video about Infrared Diag\u00adno\u00adsis to learn more about this&nbsp;topic!<\/p>\n<div style=\"width: 640px; float: right; max-width: 100%;\">\n<div style=\"width: 320px;\" class=\"wp-video\"><video class=\"wp-video-shortcode\" id=\"video-129-1\" width=\"320\" height=\"240\" preload=\"metadata\" controls=\"controls\"><source type=\"video\/mp4\" src=\"https:\/\/www.theta-dresden.de\/wp-content\/uploads\/2022\/04\/Theta_eng.mp4?_=1\"><a href=\"https:\/\/www.theta-dresden.de\/wp-content\/uploads\/2022\/04\/Theta_eng.mp4\">https:\/\/www.theta-dresden.de\/wp-content\/uploads\/2022\/04\/Theta_eng.mp4<\/a><\/video><\/div>\n<\/div>\n<div style=\"clear: both;\">&nbsp;<\/div>\n<p style=\"text-align: right;\"><a href=\"https:\/\/www.theta-dresden.de\/en\/services\"><span style=\"color: #fa2121;\">Return to overview<\/span><\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>To Deter\u00admine the Resid\u00adual Life\u00adtime of Elec\u00adtri\u00adcal Joints and Con\u00adtacts using Infrared Mea\u00adsure\u00adment Elec\u00adtri\u00adcal equip\u00adment is age\u00ading \u2014 the pro\u00adduced pow\u00ader dis\u00adsi\u00adpa\u00adtion is con\u00adstant\u00adly increas\u00ading. Nev\u00ader\u00adthe\u00adless, elec\u00adtric switchgears should be oper\u00adat\u00aded as inten\u00adsive\u00adly and as long as pos\u00adsi\u00adble, since they are extreme\u00adly expen\u00adsive. As a con\u00adse\u00adquence, such instal\u00adla\u00adtions have to be inspect\u00aded reg\u00adu\u00adlar\u00adly. In order\u2026 <br> <a class=\"read-more\" href=\"https:\/\/www.theta-dresden.de\/en\/infrared-diagnosis\">Read more<\/a><\/p>\n","protected":false},"author":1,"featured_media":41,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"wp_typography_post_enhancements_disabled":false,"footnotes":""},"class_list":["post-129","page","type-page","status-publish","has-post-thumbnail","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.4 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Infrared Diagnosis - THETA Ingenieurb\u00fcro GmbH<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.theta-dresden.de\/en\/infrared-diagnosis\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Infrared Diagnosis - THETA Ingenieurb\u00fcro GmbH\" \/>\n<meta property=\"og:description\" content=\"To Determine the Residual Lifetime of Electrical Joints and Contacts using Infrared Measurement Elec\u00adtri\u00adcal equip\u00adment is age\u00ading \u2014 the pro\u00adduced pow\u00ader dis\u00adsi\u00adpa\u00adtion is con\u00adstant\u00adly increas\u00ading. Nev\u00ader\u00adthe\u00adless, elec\u00adtric switchgears should be oper\u00adat\u00aded as inten\u00adsive\u00adly and as long as pos\u00adsi\u00adble, since they are extreme\u00adly expensive. As a con\u00adse\u00adquence, such instal\u00adla\u00adtions have to be inspect\u00aded reg\u00adu\u00adlar\u00adly. In order&hellip; Read more\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.theta-dresden.de\/en\/infrared-diagnosis\" \/>\n<meta property=\"og:site_name\" content=\"THETA Ingenieurb\u00fcro GmbH\" \/>\n<meta property=\"article:modified_time\" content=\"2025-09-30T08:02:50+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.theta-dresden.de\/wp-content\/uploads\/2019\/12\/Thermografie01-150x150-1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"150\" \/>\n\t<meta property=\"og:image:height\" content=\"150\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.theta-dresden.de\\\/en\\\/infrared-diagnosis\",\"url\":\"https:\\\/\\\/www.theta-dresden.de\\\/en\\\/infrared-diagnosis\",\"name\":\"Infrared Diagnosis - THETA Ingenieurb\u00fcro GmbH\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.theta-dresden.de\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.theta-dresden.de\\\/en\\\/infrared-diagnosis#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.theta-dresden.de\\\/en\\\/infrared-diagnosis#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.theta-dresden.de\\\/wp-content\\\/uploads\\\/2019\\\/12\\\/Thermografie01-150x150-1.jpg\",\"datePublished\":\"2019-12-26T15:34:35+00:00\",\"dateModified\":\"2025-09-30T08:02:50+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.theta-dresden.de\\\/en\\\/infrared-diagnosis#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.theta-dresden.de\\\/en\\\/infrared-diagnosis\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.theta-dresden.de\\\/en\\\/infrared-diagnosis#primaryimage\",\"url\":\"https:\\\/\\\/www.theta-dresden.de\\\/wp-content\\\/uploads\\\/2019\\\/12\\\/Thermografie01-150x150-1.jpg\",\"contentUrl\":\"https:\\\/\\\/www.theta-dresden.de\\\/wp-content\\\/uploads\\\/2019\\\/12\\\/Thermografie01-150x150-1.jpg\",\"width\":150,\"height\":150},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.theta-dresden.de\\\/en\\\/infrared-diagnosis#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Startseite\",\"item\":\"https:\\\/\\\/www.theta-dresden.de\\\/en\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Infrared Diagnosis\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.theta-dresden.de\\\/#website\",\"url\":\"https:\\\/\\\/www.theta-dresden.de\\\/\",\"name\":\"THETA Ingenieurb\u00fcro GmbH\",\"description\":\"Dienstleistungen rund um die Elektro-Energietechnik\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.theta-dresden.de\\\/#organization\"},\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.theta-dresden.de\\\/#organization\",\"name\":\"THETA Ingenieurb\u00fcro GmbH\",\"alternateName\":\"THETA\",\"url\":\"https:\\\/\\\/www.theta-dresden.de\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.theta-dresden.de\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.theta-dresden.de\\\/wp-content\\\/uploads\\\/2019\\\/12\\\/cropped-cropped-Favicon.png\",\"contentUrl\":\"https:\\\/\\\/www.theta-dresden.de\\\/wp-content\\\/uploads\\\/2019\\\/12\\\/cropped-cropped-Favicon.png\",\"width\":512,\"height\":512,\"caption\":\"THETA Ingenieurb\u00fcro GmbH\"},\"image\":{\"@id\":\"https:\\\/\\\/www.theta-dresden.de\\\/#\\\/schema\\\/logo\\\/image\\\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Infrared Diagnosis - THETA Ingenieurb\u00fcro GmbH","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.theta-dresden.de\/en\/infrared-diagnosis","og_locale":"en_US","og_type":"article","og_title":"Infrared Diagnosis - THETA Ingenieurb\u00fcro GmbH","og_description":"To Determine the Residual Lifetime of Electrical Joints and Contacts using Infrared Measurement Elec\u00adtri\u00adcal equip\u00adment is age\u00ading \u2014 the pro\u00adduced pow\u00ader dis\u00adsi\u00adpa\u00adtion is con\u00adstant\u00adly increas\u00ading. Nev\u00ader\u00adthe\u00adless, elec\u00adtric switchgears should be oper\u00adat\u00aded as inten\u00adsive\u00adly and as long as pos\u00adsi\u00adble, since they are extreme\u00adly expensive. As a con\u00adse\u00adquence, such instal\u00adla\u00adtions have to be inspect\u00aded reg\u00adu\u00adlar\u00adly. In order&hellip; Read more","og_url":"https:\/\/www.theta-dresden.de\/en\/infrared-diagnosis","og_site_name":"THETA Ingenieurb\u00fcro GmbH","article_modified_time":"2025-09-30T08:02:50+00:00","og_image":[{"width":150,"height":150,"url":"https:\/\/www.theta-dresden.de\/wp-content\/uploads\/2019\/12\/Thermografie01-150x150-1.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.theta-dresden.de\/en\/infrared-diagnosis","url":"https:\/\/www.theta-dresden.de\/en\/infrared-diagnosis","name":"Infrared Diagnosis - THETA Ingenieurb\u00fcro GmbH","isPartOf":{"@id":"https:\/\/www.theta-dresden.de\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.theta-dresden.de\/en\/infrared-diagnosis#primaryimage"},"image":{"@id":"https:\/\/www.theta-dresden.de\/en\/infrared-diagnosis#primaryimage"},"thumbnailUrl":"https:\/\/www.theta-dresden.de\/wp-content\/uploads\/2019\/12\/Thermografie01-150x150-1.jpg","datePublished":"2019-12-26T15:34:35+00:00","dateModified":"2025-09-30T08:02:50+00:00","breadcrumb":{"@id":"https:\/\/www.theta-dresden.de\/en\/infrared-diagnosis#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.theta-dresden.de\/en\/infrared-diagnosis"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.theta-dresden.de\/en\/infrared-diagnosis#primaryimage","url":"https:\/\/www.theta-dresden.de\/wp-content\/uploads\/2019\/12\/Thermografie01-150x150-1.jpg","contentUrl":"https:\/\/www.theta-dresden.de\/wp-content\/uploads\/2019\/12\/Thermografie01-150x150-1.jpg","width":150,"height":150},{"@type":"BreadcrumbList","@id":"https:\/\/www.theta-dresden.de\/en\/infrared-diagnosis#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Startseite","item":"https:\/\/www.theta-dresden.de\/en"},{"@type":"ListItem","position":2,"name":"Infrared Diagnosis"}]},{"@type":"WebSite","@id":"https:\/\/www.theta-dresden.de\/#website","url":"https:\/\/www.theta-dresden.de\/","name":"THETA Ingenieurb\u00fcro GmbH","description":"Dienstleistungen rund um die Elektro-Energietechnik","publisher":{"@id":"https:\/\/www.theta-dresden.de\/#organization"},"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.theta-dresden.de\/#organization","name":"THETA Ingenieurb\u00fcro GmbH","alternateName":"THETA","url":"https:\/\/www.theta-dresden.de\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.theta-dresden.de\/#\/schema\/logo\/image\/","url":"https:\/\/www.theta-dresden.de\/wp-content\/uploads\/2019\/12\/cropped-cropped-Favicon.png","contentUrl":"https:\/\/www.theta-dresden.de\/wp-content\/uploads\/2019\/12\/cropped-cropped-Favicon.png","width":512,"height":512,"caption":"THETA Ingenieurb\u00fcro GmbH"},"image":{"@id":"https:\/\/www.theta-dresden.de\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/www.theta-dresden.de\/en\/wp-json\/wp\/v2\/pages\/129","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.theta-dresden.de\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.theta-dresden.de\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.theta-dresden.de\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.theta-dresden.de\/en\/wp-json\/wp\/v2\/comments?post=129"}],"version-history":[{"count":10,"href":"https:\/\/www.theta-dresden.de\/en\/wp-json\/wp\/v2\/pages\/129\/revisions"}],"predecessor-version":[{"id":1131,"href":"https:\/\/www.theta-dresden.de\/en\/wp-json\/wp\/v2\/pages\/129\/revisions\/1131"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.theta-dresden.de\/en\/wp-json\/wp\/v2\/media\/41"}],"wp:attachment":[{"href":"https:\/\/www.theta-dresden.de\/en\/wp-json\/wp\/v2\/media?parent=129"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}